¢Æ HOME > Àü±â/ÀüÀÚ/±â·Ï°è > ¸ÖƼ¹ÌÅÍ
Dual Channel Datalogging Digital Multimeter
¸ðµ¨¸í : Prova-903(RS-232,RMS
Á¦Á¶»ç : TES
¿ø»êÁö : TAIWAN
°¡°Ý :

Dual Channel Digital Multimeter Prova-901(RS-232,RMS)

Dual Channel Datalogging Digital Multimeter Prova-903(RS-232,RMS)

¡Ü Á¦Ç°Æ¯Â¡

  • 60,000 counts and dual input channels (4-5/6 digits)
  • 0.03% DC basic accuracy and 0.1% AC basic accuracy
  • Bandwidth of 200 KHz(max.) and true RMS
  • Fast ACV, ACA response
  • Better AC accuracy than that of a bench-top DMM
  • Study of relationship of two voltages similar to a dual channels DSO
  • Study of relationship of voltage and current with one DMM
  • Dual display of frequency and duty cycle
  • Record data of both channels using a PC through the RS-232 interface
  • Standalone data logging of 10,708 records for both channels (903)

¡Ü Á¦Ç°»ç¾ç

ELECTRICAL SPECIFICATIONS : ( 23¡É¡¾5¡É and <75% RH)

¡á DC Voltage : (Input Impedance : 10M §Ù )

Range

Resolution

Accuracy Overload Protection
60.000mV 0.001mV

¡¾ 0.1% ¡¾5 dgts 1

DC 1000V
600.00mV 0.01mV

¡¾ 0.02% ¡¾3 dgts 2

DC 1000V
6.0000V 0.0001V

¡¾ 0.02% ¡¾3 dgts

DC 1000V
60.000V

0.001V

¡¾ 0.02% ¡¾3 dgts

DC 1000V
600.00V 0.01V

¡¾ 0.02% ¡¾3 dgts

DC 1000V
1000.0V 0.1V

¡¾ 0.04% ¡¾3 dgts

DC 1000V

¡á AC voltage :

Range (ACV)

Resolution

Accuracy(50/60Hz)

60.000mV

0.001mV

¡¾ 0.1% ¡¾2 0dgts

600.00mV

0.01mV

¡¾ 0.1% ¡¾2 0dgts

6.0000V

0.0001V

¡¾ 0.1% ¡¾2 0dgts

60.000V

0.001V

¡¾ 0.1% ¡¾2 0dgts

600.00V

0.01V

¡¾ 0.1% ¡¾2 0dgts 1

1000.0V

0.1V

¡¾ 0.1% ¡¾2 0dgts

¡á DC Current :

Range

Resolution

Accuracy

600.00 §Ë

0.01 §Ë

¡¾ 0.2% ¡¾1 0dgts

6000.0 §Ë

0.1 §Ë

¡¾ 0.1% ¡¾1 0dgts

60.000mA

0.001mAA

¡¾ 0.2% ¡¾1 0dgts

600.00mA

0.01mA

¡¾ 0.1% ¡¾1 0dgts

1.0000A

0.0001A

¡¾ 0.1% ¡¾1 0dgts

10.000A 1

0.001A

¡¾ 0.3% ¡¾1 0dgts

1 20A overload for maximum 30 seconds

¡á AC Current :

Range(ACA)

Resolution

Accuracy(50/60Hz)

600.00 §Ë

0.01 §Ë

¡¾ 0.3% ¡¾2 0dgts

6000.0 §Ë

0.1 §Ë

¡¾ 0.3% ¡¾2 0dgts

60.000mA

0.001mA

¡¾ 0.3% ¡¾2 0dgts

600.00mA

0.01mA

¡¾ 0.3% ¡¾2 0dgts

1.0000A

0.0001A

¡¾ 0.3% ¡¾2 0dg ts

10.000A 1

0.001A

¡¾ 0.5% ¡¾2 0dgts

1 20A overload for maximum 30 seconds

¡á Resistance(§Ù) :

Range Resolution Accuracy Overload Protection
999.99 §Ù 0.01 §Ù

¡¾ 0.15% ¡¾8 dgts

AC 1000V
9.9999K §Ù 0.0001K §Ù

¡¾ 0.09% ¡¾3 dgts

AC 1000V
99.999K §Ù 0.001K §Ù

¡¾ 0.09% ¡¾3 dgts

AC 1000V
999.99K §Ù 0.01K §Ù

¡¾ 0.09% ¡¾3 dgts

AC 1000V
9.9999M §Ù 0.0001M §Ù

¡¾ 0.2% ¡¾6 dgts

AC 1000V
40.000M §Ù

0.001M §Ù

¡¾1 % ¡¾6 dgts

AC 1000V

¡á Continuity : (Open voltage 3V approx.)

Range

Resolution

Beeper

Overload protection

999.99 §Ù

0.01§Ù

<40§Ù approx

AC 1000V

¡á Capacitance : (¦¾¦¼, auto range, and for film capacitor or better)

Range

Resolution

Accuracy 1

60.00nF

0.01nF

¡¾0.8 % ¡¾5 dgts

600.0nF

0.1nF

¡¾1.5 % ¡¾5 dgts

6.000§Þ

0.001§Þ

¡¾1.5 % ¡¾5 dgts

60.00§Þ

0.01§Þ

¡¾2.0 % ¡¾5 dgts

600.0§Þ

0.1§Þ

¡¾3.5 % ¡¾5 dgts

1 for reading less than 150 counts(least significant digits),
add additional 15 digits to the specified accuracy.

¡á Capacitance : (¦¾¦¼, manual range, and for film capacitor or better)

Range

Resolution

Accuracy 1

99.99nF

0.01nF

¡¾0.8 % ¡¾5 dgts

999.9nF

0.1nF

¡¾1.5 % ¡¾5 dgts

9.999§Þ

0.001§Þ

¡¾1.5 % ¡¾5 dgts

99.99§Þ

0.01§Þ

¡¾2 % ¡¾5 dgts

999.9§Þ

0.1§Þ

¡¾3.5 % ¡¾5 dgts

1 for reading less than 150 counts(least significant digits),
add additional 15 digits to the specified accuracy.

¡á Diode Test : (open voltage 3V approx, overload protection AC 1000V)

Range

Resolution

Accuracy

Short Circuit Current

3.0000V

0.0001V

¡¾2%rdg ¡¾ 5dgts

0.8mA Typical

¡á Frequency : (TTL)

Range(Auto)

Resolution

Accuracy

Overload Protection

1.000Hz-2MHz

0.0001Hz-0.0001MHz

¡¾0.005%rdg + 4dgts

AC 1000V

¡á Duty Cycle : (%, TTL, 1Hz-600KHz)

Range

Resolution

Accuracy

Overload Protection

0.001%-9.999%

0.001%

¡¾30d/KHz¡¾30dgts

AC 1000V

10.00%-100.00%

0.01%

¡¾3d/KHz¡¾3dgts

AC 1000V

¡á Frequency : (AC sine wave)

Range(Auto)

Resolution

Accuracy

Overload Protection

1.0000Hz-200KHz

0.0001Hz-100Hz

¡¾0.02%rdg + 4dgts

AC 1000V

Sensitivity (Sine wave)
100 mV min @ mV range
1 V min @ V range

¡á Duty Cycle : (%, sine wave)

Range(Auto)

Resolution

Accuracy

Overload Protection

0.001%-100.00%

0.001%-0.01%

Not specified

AC 1000V

GENERAL SPECIFICATIONS :

  • Battery Type : 9V
  • Display : 5 + 5 digits LCD with 30 segments bar graph
  • Range Selection : auto and manual
  • Overload Indication : OL
  • Power Consumption : 6mA (approx)
  • Dimensions : 207mm(L) x 101mm(W) x 47mm(H)
  • Weight : 430g(battery included)
  • Accessories : Users manual x 1, 9V battery x 1, Test Leads,
    Alligator clips, RS-232C interface cable, Software
±¸ºÐ Á¦ ¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ
µî·ÏµÈ ±ÛÀÌ ¾ø½À´Ï´Ù.
µî·ÏµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 

°í°´¼¾ÅÍ : 02-742-0727 / Æѽº : 02-742-0729 /
°øÁ¤°Å·¡À§¿øȸ °í½Ã Á¦ 2004-1È£¿¡ µû¸¥ »ç¾÷ÀÚµî·Ï¹øÈ£ ¾È³» : 101-86-66046
ÁÖ ¼Ò : ¼­¿ïƯº°½Ã ±Ýõ±¸ µðÁöÅзΠ121 (¿¡À̽º°¡»êŸ¿ö) 9Ãþ 903È£

´ëÇ¥ÀÌ»ç : ±èÁøȲ Copyright(C) 2007 TMI21 All rights reserved